Frame made of aluminium profile bars connected by "Tox" connections
- All-round EPDM lip seal
- Restraint security
- Hidden latches
- Screwed GKF gypsum plasterboard
Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018EN 1634-1: +A1: 2018
Fire dampers EI 60 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60.
They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop.
The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Pour le PCD, la gamme des différentes nuances est plus restreinte que pour le PcBN, ce qui simplifie beaucoup le choix. Les nuances se différencient principalement par leur microstructure, ainsi que par la taille de grain. MAPAL offre ici une sélection de nuances qui ont fait leurs preuves et qui sont les mieux indiquées pour des plaquettes performantes et de haute précision.
Pour les matériaux à copeaux longs, comme par exemple les alliages d’aluminium à faible teneur en silice, MAPAL propose des plaquettes avec brise copeau. Deux variantes sont disponibles en standard, offrant toutes deux une structure spécialement développée pour une casse du copeau maîtrisée, pour l’usinage de finition et l’usinage à forte profondeur de coupe. Les copeaux sont comprimés et cassés sans coller à la structure de la pièce et sans formation d’arête rapportée.
Frame made of aluminium profile bars connected by "Tox" connections
- All-round EPDM lip seal
- Restraint security
- Hidden latches
- Screwed GKF gypsum plasterboards
Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018
Fire dampers EI 120 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 120.
They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop.
The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Frame made of aluminium profile bars connected by "Tox" connections
- Intumescent gas, smoke and flame tight seal in case of fire
- Restraint security
- Hidden latches
- Screwed GKF gypsum plasterboards
- Quick and easy installation
The 60-minute ceiling fire dampers are designed for installation in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60.
They provide effective protection against fire progression from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop.
The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms. The safety catching arms ensure that the lid is intercepted every time the hatch is opened. The lid is easy to remove and replace.
Tissu 67% COTON 33% POLYESTER IR, chaine & tram e Retors, arm ure toile 1/1, 190g/m2, 150cm, nonimper
Principales utilisations:foulards m ilitaires, tentes legeres et cam ouflage lorsque traite 2i